Описание

  • 3-stage function
  • Dual-channel version
  • 22.5 mm installation dimension
3-stage function Enabling function is active only in the second stage (middle position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence). Switching element
22022NO/NC 1) From position 1 to position 2 –> NO contact, from position 2 to position 3 –> NC contact.
Dimension drawing 2202 Dimension drawing2202 Technical dataApprovals Mechanical values and environment
Rated actuating force according to EN 60947-5-8 max.100 N
Material
Protective cap CR
Housing material Polyamide
Weight
Net 0,03 kg
Ambient temperature -5 ... 60 °C
Degree of protection
On the front IP65
Connections IP00
Mechanical life
Position 1-2-1 min.0,1 x 106 cycles
Position 1-2-3-1 min.0,1 x 106 cycles
Installation orientation Any
Tightening torque
Screws max.0,15 Nm
Number of switching elements 2 NO
Connection Screw terminal 4-pole
Stripping length 5 mm
Actuating force max.50 N
Electrical connection ratings
Rated conditional short-circuit current 100 A
Utilization category according to EN 60947-5-2
DC-13 0.1A 24V
Fusing
external 0,1 A Medium slow-blow
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Switching current 5 ... 100 mA
Degree of contamination (external, according to EN 60947-1) 3
Connection cross-section
single conductor 0,33 ... 1,5 mm?
multiple conductor 0,33 ... 0,75 mm?
Connection cross-section, AWG
single conductor 22 ... 16 AWG
multiple conductor 22 ... 18 AWG
Breaking capacity max.0,25 W
Other
In compliance with DIN EN 60947-5-8
Color
Housing Black
Protective cap Black
Reliability values according to EN ISO 13849-1
B10D 0,75 x 106
''