Описание

  • 2-stage function
  • Button for enabling function
  • Dual-channel version
  • 34.4 mm installation dimension
  • Suitable, e.g. for installation in the hand-held pendant stations HBL or housing G2 or G3
Switching elements
202NO 2) As per VDI 2854, a device comparable to an emergency stop device must be fitted!
2-stage function Enabling function is active in the second stage (pressed position). When the button is released, the enabling is removed (see function sequence). Dimension drawing 20 Dimension drawing20 Technical dataApprovals Mechanical values and environment
Material Plastic
Weight
Net 0,25 kg
Ambient temperature -5 ... 50 °C
Degree of protection IP65
Mechanical life
Position 1-2-1 0,1 x 106
Switching principle Slow-action contact element
Number of NO contacts 2
Connection Tab connector 2.8 x 0.8 IEC 760
Electrical connection ratings
Rated conditional short-circuit current 100 A
Utilization category according to EN 60947-5-1
AC-15 3.3A 24V
DC-13 3A 24V
Short circuit protection according to IEC 60269-1 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Degree of contamination (external, according to EN 60947-1) 3
Switching characteristics 2-stage push button
Other
In compliance with 60947-5-1
''