Описание

  • Metal plug
  • Miniature design
  • Red light
A reflector must be used in combination with these sensors. They can be installed in all kinds of industrial environments thanks to ample functional reserve. Even reflective objects can be reliably recognized through the use of polarized light.
Range 4500 mm
Reference Reflector/Reflector Foil RQ100BA
Switching Hysteresis < 15 %
Light Source Red Light
Polarization Filter yes
Service Life (T = +25 °C) 100000 h
Max. Ambient Light 10000 Lux
Opening Angle 5 °
Light Spot Diameter see Table 1
Two-Lens Optic yes
Electrical Data
Supply Voltage 10...30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Switching Frequency 1 kHz
Response Time 500 µs
Temperature Drift < 10 %
Temperature Range -25...60 °C
Switching Output Voltage Drop < 2,5 V
PNP Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III
Mechanical Data
Setting Method Potentiometer
Housing Material Plastic
Full Encapsulation yes
Degree of Protection IP67
Connection M8 ? 1, 4-pin
Safety-relevant Data
MTTFd (EN ISO 13849-1) 2329,49 a
Output
PNP NO/NC antivalent yes
''