Описание

Amplifier Unit, Connector Type, NPN
Model PX-10C
Type Connector type
Output NPN
Response time 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
Output selection LIGHT-ON/DARK-ON
Indicator lamp - Operation indicator:Red LED x 2, DSC orange LED x 1 - Dual digital monitor:Dual 7-segment display [Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together, current value range:0 to 65504, excess gain:0 P to 999 P] - Hold function:Possible to display both peak and bottom hold values. Selectable from 5 variations. - Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)] - Scaling display
Detection mode Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]
Shift function Variable between –1999 and 9999
Timer function Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot Timer duration selectable:1 ms to 9999 ms Maximum error against the setting value:10% max.
Control output NPN open-collector 40 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.
External input ?
Interference prevention Up to 4 units (in all power modes)*1
Rating Power voltage 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2
Power consumption Standard mode:50 mA max. at 24 V/55 mA max. at 12 V Power saving mode:40 mA max. at 24 V/45 mA max. at 12 V
Environmental resistance Enclosure rating IEC: IP67/JEM: IP67/NEMA: 4X
Ambient temperature -10 to +55 °C (No freezing)*3
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Case material Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR
Weight Approx. 50 g
*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected somewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts. *2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m or more (PX-H71/H71TZ) or 10 m or more (PX-H72). *3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below. 2 to 4 Units: -10 to +50 °C, 5 to 17 Units: -10 to +45 °C.
''