Описание

Rectangular w/ cable Type, 250 mm
Model LR-ZB250N
Type Distance based laser sensor
Shape Rectangular
Output NPN
Cable connection 2 m cable
Detectable distance 35 to 250 mm (215 to 0)*1
Standard detectable deviation 35 to 180 mm: 9 mm 180 to 250 mm: 25 mm
Display resolution 1 to 3 (1 to 3 mm)
Spot diameter Approx. 2.4 ? 1.2 mm at 250 mm
Response time 1.5 ms / 10 ms / 50 ms selectable
Light source Type Red laser (660 nm)
Laser class Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*2)
Function Indicator 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green)
Timer OFF/ON delay/OFF delay/One-shot
Rating Power voltage 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Power consumption 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)
Specifications Control output NPN Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA
Protection circuit Protection against reverse power connection, output overcurrent, output surge, reverse output connection
Output operation Light-ON / Dark-ON selectable
External input Input time calibration: 35 ms or more ON, 35 ms or more OFF Laser emission stop: 2 ms or more ON, 20 ms or more OFF Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less
Environmental resistance Enclosure rating IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3
Insulation resistance 20 M? or more (500 VDC)
Ambient light Incandescent lamp: 2,000 lux or less Sunlight: 4,000 lux or less*4
Ambient temperature -10 to +50 °C (No freezing)
Storage temperature -25 to +75 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Withstand voltage 1,000 VAC, 50/60 Hz, 1 min
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM
Accessories Instruction Manual, Certification/Identification label (FDA)
Weight Approx. 110 g (Including cable)
*1 Display reading used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds “-99”, “-FF” is displayed. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 Have passed resistance tests with cleaning agents from multiple manufactures. *4 When the response time is 10 ms
''