Описание

Fibre Amplifier, Zero-line Expansion Unit
Model FS-T0
Type 0-line expansion unit
Output -
Light source Red LED
Sensitivity adjustment/Mode selection Button
Response time 410 µs to 1 ms*1
Operation mode LIGHT-ON/DARK-ON (switch-selectable)
Indicator lamp Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED
Timer function ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)
Input Non-voltage input (contact, solid state)
Control output ?
Stability output
Protection circuit Reversed polarity protection, Overcurrent protection, Surge absorber
Unit expansion Up to 16 expansion units can be connected (a total of 17 units)*2
Mutual interference suppression FINE : 4, TURBO/SUPER: 8
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*3
Current consumption 35 mA or less
Environmental resistance Ambient light Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.
Ambient temperature -10 to +55 °C (No freezing)*4
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Polycarbonate
Weight Approx. 20 g
*1 The response speed varies depending on the number of expansion units connected. *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F) *3 Power to the FS-T2/T0/M2/M0 is supplied through the FS-T1/M1/V1/V11/R0, PS-T1, LV-21A/11A or CZ-V1. *4 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended
''