Описание

Amplifier Unit, Main Unit, NPN
Model CZ-V21
Output NPN output
Main unit/Expansion unit Main unit
Response time 8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED)
Control output NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1
Protection circuit Reverse-polarity protection, overcurrent protection, surge absorber
External calibration input No-voltage input, input time: 20 ms or more
External shift input
Timer function Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)
Unit expansion Up to 3 units (4 units total including the main unit)*2
Rating Power voltage 24 VDC, Ripple (P-P) 10 % or less
Power consumption Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)
Environmental resistance Ambient temperature -10 to +55 °C (No freezing)*3
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis
Material Housing, cover: Polycarbonate
Weight Approx. 110 g
*1 20 mA max. when several units are connected. *2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series. *3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA. When 1 or 2 units are connected: -10 to +50 °C When 3 units are connected: -10 to +45 °C
''