Описание

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Plug connector M8, 8-pin
  • Multicode
Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 FI1B Enable input for channel 2 WH
2 UB Power supply, DC 24 V BN
3 FO1A Safety output, channel 1 GN
4 FO1B Safety output, channel 2 YE
5 OD Monitoring output GY
6 FI1A Enable input for channel 1 PK
7 0V Ground, DC 0 V BU
8 RST Reset input RD
Material
Rubber support NBR 80 ±5 Shore
Housing material Plastic, PBT
Weight
Net 0,04 kg
Ambient temperature -25 ... 65 °C
Degree of protection IP67 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.140 mm
Installation orientation Any
Tightening torque
Fixing screws max.0,8 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection M8 plug connector, 8-pin
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Monitoring output OD
Type of output Semiconductor output, p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.1,0 ms
Test-pulse interval min.140 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Rubber support included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance
Approach direction C or D (broad side) 15 mm
Approach direction A or B (front side) 19 mm
Assured operating distance Sao
Approach direction C or D (broad side) min.10 mm
Approach direction A or B (front side) min.14 mm
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance
Approach direction A or B (front side) 15 mm
Approach direction C or D (broad side) 11 mm
Assured operating distance Sao
Approach direction C or D (broad side) 6
Approach direction A or B (front side) 10
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar
In x/z direction max.40 mm
In y direction max.60 mm
Switching hysteresis min.1 mm
''