Описание

  • 100 detent positions per revolution
  • Wear-free magnetic detent mechanism
  • 25 pulses per revolution
  • Installation in operator panels and EUCHNER hand-held pendant stations HBL
Dimension drawing Wiring diagram Ausgangssignale Hand-held pendant stations and hand wheels Dimension drawingWiring diagramAusgangssignale Technical dataApprovals Mechanical values and environment
Material Aluminum
Weight
Net 0.5
Ambient temperature 0 ... 70 °C
Atmospheric humidity
(condensation not permissible) 0.8
Degree of protection
IEC 529 IP65
acc. to NEMA 250 250-12
Resilience to vibration
Vibration (3 axes) DIN/IEC 68-2-6
Shock (3 axes) DIN/IEC 68-2-27
Tightening torque max.0,5 Nm
Connection Screw terminal 6-pole
Detent positions per revolution 100
Electrical connection ratings
Operating voltage DC 10 ... 30 V DC
Current consumption
Without load max.80 mA
EMC protection requirements
Acc. to CE EN 61000-6-2, EN 61000-6-4
Type of output Push-pull
Connection cross-section 0,08 ... 2,5 mm?
Connection cross-section, AWG 28 ... 12 AWG
Pulses per revolution 2x25
Output voltage
High(1) min.4,9 V DC at 0 mA
min.3,9 V DC at 5 mA
min.3,6 V DC at 20 mA
Low(0) max.1,3 V DC at 15 mA
Other
Detent mechanism Magnetic
''