Описание

  • Membrane keypad can be labeled as required using slide-in strips
  • Tamper-proof EMERGENCY STOP device according to EN 13850, dual-channel
  • LEDs white, color customer-specific using colored keypad membrane
  • 2 pushbuttons 2-stage, 1 NO contact each, e.g. for enabling function
  • Coiled cable, expandable to 5 m, 35-pin plug connector
Notes
  • For template for slide-in strips, see www.euchner.com (Service)
Dimension drawing Wiring diagram Hand-held pendant stations and hand wheels Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Material Polycarbonate
Weight
Net 1,5 kg
Ambient temperature 0 ... 50 °C
Atmospheric humidity
(condensation not permissible) max.80 % rH
Degree of protection
IEC529 IP65
Acc. to Nema 205-12
Resilience to vibration
Vibrations (3 axes) DIN/IEC 68-2-6
Shock (3 axes) DIN/IEC 68-2-27
Connection Plug connector
Cable length
coiled 5,00 m
Electrical connection ratings
Utilization category according to EN 60947-5-1
DC-13 24V DC / 3A
Switching voltage
Pushbuttons max.DC 50 V
max.AC 32 V
Membrane keypad max.DC 42 V
max.AC 25 V
Switching current
Pushbuttons max.100 mA
Membrane keypad max.100 mA
EMC protection requirements
Acc. to CE EN 61000-6-2, EN 61000-6-4
Connecting cable 35x0.14
Breaking capacity (VA)
Membrane keypad max.1 VA
Power supply LED 24V V DC -10% ... +10% V DC
Controls and indicators
Control/indicator
Ausfuhrung Membrane keys
Einlegeschild
Extras -
Farbe -
Schaltelement 1 NO contact each
Position See data sheets
Control/indicator
Ausfuhrung LED
Einlegeschild
Extras -
Farbe white
Schaltelement -
Position See data sheets
Control/indicator
Ausfuhrung Push button
Einlegeschild
Extras -
Farbe -
Schaltelement 1 NO contact each
Position See data sheets
Control/indicator
Ausfuhrung Emergency stop
Einlegeschild
Extras -
Farbe Red-yellow
Schaltelement 2 positively driven contacts
Position See data sheets
Other
Additional feature
Exchangeable slide-in strips
Color
Housing Gray RAL 7040
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
''