Описание

  • Plunger spacing 12 or 16 mm
  • Horizontal housing
  • Degree of protection IP67 according to IEC 60529
  • LED function display optional
Switching elements
ES 502 ESnap-action switching contact 1 NC + 1 NO
ES 508Slow-action switching contact 1 NC
ES 514Snap-action switching contact 1 NC + 1 NO
On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN 1088, i.e. riveted, welded or secured in some other way against becoming loose. LED function display (optional)Function displays are available for the following voltage ranges (see accessories)
LE06012 ... 60 V AC/DC
LE110110 V AC ±15%
LE220220 V AC ±15%
Dimension drawing ES 502 E ES 508 ES 514 Dimension drawingES 502 EES 508ES 514 Technical dataApprovals Mechanical values and environment
Contact bounce time < 3ms
Contact closing time < 4ms
Design Horizontal
Housing material Sand-cast aluminum, anodized
Weight
Net 1,9 kg
Ambient temperature -5 ... 80 °C
Degree of protection IP67
Mechanical life 30 x 106
Contact material Silver alloy, gold flashed
Switching principle Snap-action switching contact
Plunger spacing 12 mm
Installation orientation Any
Number of switching elements 4
Number of NC contacts 4
Number of NO contacts 4
Connection 3 x M25 x 1.5
Approach speed 0,01 ... 80 m/min
Actuating element Roller plunger
Roller diameter 8 mm
Actuating force min.20 N
Operating point accuracy ± 0.01
Electrical connection ratings
Thermal rated current Ith 8 A
Utilization category according to EN 60947-5-1
AC-15 6A 230V
DC-13 6A 24V
AC-12 8 A, 250 V
Short circuit protection according to IEC 60269-1
(Fuse) 8A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching current
Min. at DC 12V min.10 mA
Connection cross-section 0,34 ... 1,5 mm?
Other
C number
C2050
''