Описание

  • With reed contact
  • Plunger material stainless steel
  • Any installation position
Switching elementReed contact, 1 NO contact Never switch incandescent lamps. Not even for test purposes. Single hole fixing limit switches must not be used as an end stop. Dimension drawing Wiring diagram Wiring diagram Dimension drawingWiring diagramWiring diagram Technical dataApprovals Mechanical values and environment
Design Thread M14 x 1
Housing material
Sleeve Brass, nickel-plated
Threaded section Stainless steel
Ambient temperature -25 ... 80 °C
Degree of protection IP67
Mechanical life 30 x 106
Contact material Rhodium
Switching principle Reed contact
Repeat accuracy (absolute) ±0,01 mm
Installation orientation Any
Number of NO contacts 1
Connection Plug connector M12
Approach speed max.8 m/min
Actuating element Ball plunger
Actuating force
Approx. 16 N
Electrical connection ratings
Utilization category according to EN 60947-5-1
DC-13 0.3A 24V
AC-12 0.3A 30V
Short circuit protection according to IEC 60269-1 0.4A gG
Rated insulation voltage Ui 50 V
Switching voltage
min. 1 V
Switching current
Min. at 24V 1 mA
''