  • For connecting MGB2 or MCM modules
  • Connection to PROFINET with PROFIsafe
  • Connection via plug connector M12, D-coded
  • Remote or direct mounting
  • Integrated switch
  • Compatible with all Modular devices
PROFINET interface Plug connector M12 D-coded (7/8 plug and M12 plug, D-coded) according to IEC 61076-2-101 PROFINET switch Linear topology network structure due to integrated switch (supports MRP). MLI connections (module plug connector) An MGB2 Modular or an MCM Modular can be connected directly to a bus module (direct plug). Alternatively, the modules can be connected using commercially available connecting cables M12, 5-core (cable connect). Dimension drawing Dimension drawing MGB2 Modular: an overview Dimension drawingDimension drawing Technical dataApprovals Mechanical values and environment
Housing material Fiber glass reinforced plastic, die-cast zinc, nickel plated
Weight
Net 0,85 kg
Ambient temperature
At UB = 24V DC -25 ... 55 °C
Degree of protection IP65
Resilience to vibration In acc. with EN 60947-5-3
Installation orientation Any
Connection
7/8 Power
7/8 Power
Acc. to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12 D-coded, screened
M12 D-coded, screened
ML1C / ML2C
Type specification M12 EN 61076-2-101 / A-coded
Insertion cycles 100
Connection Screw terminal
Connection type Plug
Number of pins 5
ML1D
Insertion cycles 100
Connection Connector (unlocked)
Connection type Plug
Number of pins 5
Electrical connection ratings
Current consumption max.150 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1,5 kV
Maximum feed-in current in the connection block
XD1, XD2 max.6000 mA
EMC protection requirements EMC directive 2014/30/EU
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
MLI 5-pin, M12x1
Safety class III
Interface, bus
Data interface
Data protocol
Bus protocol Profinet (IEC 61158 type 10)
Safety protocol Profisafe (IEC 61784-3-3)
Reliability values according to EN ISO 13849-1
Performance Level PL e
PFHD 1.14 x 108
Safety Integrity Level SIL 3 (EN 62061:2005)