Описание

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With plug connector RC18
  • With escape release
  • Unicode
  • Release monitoring
Door stop A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicator The LED indicator indicates all important system and status information. Guard locking type
MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).
Auxiliary release For releasing the guard locking, e.g. in case of a power failure. Monitoring outputs
OTBolt tongue inserted into the evaluation module
OLGuard locking solenoid in locked position
OIDiagnostics, there is a fault
Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone.
    Dimension drawing Dimension drawing Plug connector RC18 MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingPlug connector RC18 Technical data Locking module MGB-L1-ARA-AA1A1-S1-L-111943 (Order no. 111943) Mechanical values and environment
    Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
    Weight
    Net 0,75 kg
    Ambient temperature
    At UB = 24V DC -20 ... 55 °C
    Degree of protection IP65
    Mechanical life 1 x 106
    In case of use as door stop, and 1 Joule impact energy 0,1 x 106
    Installation orientation Door hinge DIN left
    Switching frequency 0,25 Hz
    Connection Plug connector RC18
    Guard locking principle Closed-circuit current principle
    Locking force FZh 2000 N
    Electrical connection ratings
    Utilization category according to EN 60947-5-2
    DC-13 24V 200mA
    Rated insulation voltage Ui 30 V
    Rated impulse withstand voltage Uimp 1,5 kV
    Degree of contamination (external, according to EN 60947-1) 3
    Safety class III
    Discrepancy time
    Between FO1A and FO1B max.10 ms
    Risk time according to EN 60947-5-3 max.350 ms
    Transponder coding Unicode
    Solenoid control input IMP1, IMP2, IMM
    Test pulses max.5 ms
    Test-pulse interval min.100 ms
    Power supply UA
    Operating voltage DC
    UA 24 V DC -15% ... 10%
    Current consumption
    IUA max.375 mA
    Safety outputs FO1A, FO1B
    Test pulses max.1 ms
    Test-pulse interval min.100 ms
    Type of output Semiconductor outputs, p-switching, short circuit-proof
    Output voltage
    UFO1A /UFO1B HIGH UB-2V ... UB V DC
    UFO1A /UFO1B LOW 0 ... 1 V DC
    Output current
    Per safety output FO1A / FO1B 1 ... 200 mA
    Power supply UB
    Operating voltage DC
    UB 24 V DC -15% ... 10%
    Current consumption
    IUB max.80 mA
    Monitoring outputs OD, OT, OL, OI
    Type of output Semiconductor outputs, p-switching, short circuit-proof
    Output voltage UA-2V ... UA V DC
    Output current max.50 mA
    Other
    Product version number V3.0.3
    Reliability values according to EN ISO 13849-1
    Monitoring of guard locking and the safety guard position
    Category 4
    Performance Level PL e
    PFHD 3.7 x 10-9
    Control of the guard locking
    Category 4
    Performance Level PL e
    PFHD 2.8 x 10-9
    Mission time 20 y
    Handle module MGB-H-AA1A3-L-111158 (Order no. 111158) Mechanical values and environment
    Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
    Weight
    Net 1,00 kg
    Ambient temperature -20 ... 55 °C
    Degree of protection IP65
    Installation orientation Door hinge DIN left
    Other
    Additional feature With automatic lockout mechanism
    Product version number V3.0.0
    Escape release MGB-E-A-100465 (Order no. 100465) Mechanical values and environment
    Housing material Die-cast zinc/stainless steel powder-coated
    Weight
    Net 0,75 kg
    Ambient temperature -20 ... 55 °C
    Mechanical life 1 x 106
    Installation orientation Any
    Other
    Product version number V2.0.0
    Components 111943 Locking module MGB-L1-ARA-AA1A1-S1-L-111943
    • Guard locking with guard lock monitoring
    • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
    • With plug connector RC18
    • Unicode
    • Release monitoring
    111158 Handle module MGB-H-AA1A3-L-111158
    • Intelligent bolt tongue
    • Fold-out lockout mechanism
    • Second automatically extending lockout mechanism
    • Door handle
    100465 Escape release MGB-E-A-100465
    • Escape release from the danger zone
    • Door handle signal red
    • Extended actuation axis for thicker doors (available optionally)
    ''