Описание

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • 4 illuminated pushbuttons
  • Including adhesive labels
  • Connection via M12 plug
  • Pre-assembled on mounting plates
  • Unicode
Dimension drawing Wiring diagram MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 3,1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Reaction time
Guard locking max.250 ms Switch-off time
Emergency stop / machine stop max.100 ms Switch-off time
Door position max.250 ms Switch-off time
Bolt position max.250 ms Switch-off time
Switching frequency 0,25 Hz
Connection
M12 Power, A-coded
M12 Power, A-coded
Ethernet/IP cable, Cat. 5e min. M12 D-coded, screened
M12 D-coded, screened
Guard locking principle Closed-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Ethernet/IP cable, Cat. 5e min.
Safety class III
Transponder coding Unicode
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Work area
Assured switch-off distance Sar max.65 mm
Interface, bus
Data interface
Data protocol
Bus protocol Ethernet/IP
Safety protocol CIP Safety
Controls and indicators
Belegungsschema B1
Belegungsschema L1
Position 1
Ausfuhrung Emergency stop illuminated
Einlegeschild
Extras With adhesive ring
Farbe
Schaltelement 2 pos. driven NC
Position 90
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 92
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 93
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 95
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature Incl. cover set ID. No. 120344
Product version number V1.2
Slide-in label 4 pcs. without marking
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 3.37 x 10-9
Diagnostic Coverage (DC) 99
Control of the guard locking
Category 4
Performance Level PL e
PFHD 4.91 x 10-9
Emergency stop
B10D
Emergency stop 0.1 x 106
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 3.05 x 10-9
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20
''