Описание

  • Evaluation of signals in the field
  • Connection of CES read heads
  • Connection to the ET200s and ET200pro
  • Familiar EUCHNER AP interface
  • Unicode
Short circuit monitoring The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays. Category according to EN ISO 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (F01A and F01B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Connection for control system
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 UB Power supply, DC 24 V BN
2 FO1A Safety output, channel 1 WH
3 0V Ground, DC 0 V BU
4 FO1B Safety output, channel 2 BK
5 - n.c. GY
Connection for read head
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 H1 Data line BN
3 H2 Data line WH
4 SH Shield -
Housing material Plastic, PBT
Weight
Net 0,096 kg
Ambient temperature
Cable static -20 ... 65 °C
Cable dynamic -5 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Installation orientation Any
Tightening torque max.1 Nm
Ready delay 1 s
Switching frequency max.1 Hz
Connection Connection cable PUR with plug connector M12 5-pin, pin 5 not used
Electrical connection ratings
Operating voltage DC
UB(PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple < 5%) 24 V DC 15% ... 15%
Current consumption max.45 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Safety outputs FO1A / FO1B
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
Utilization category according to EN 60947-5-2
DC-13 DC-13 24V 150mA
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.5 x 10-9
Mission time 20
In combination with Read head CES-A-LMN-SC and Actuator CES-A-BMBOperating distance
Switch-on distance 5 mm
Assured switch-off distance Sar max.10 mm
Assured operating distance Sao min.3,4 mm
Switching hysteresis min.0,05 mm
''