Описание

  • Electromagnet for locking access doors
  • Locking force 650 N
  • With remanence
  • No guard lock monitoring, no monitoring of the door position
  • Connection using an M8 plug connector
Dimension drawing Wiring diagram Wiring diagram Dimension drawingWiring diagramWiring diagram Technical dataApprovals Mechanical values and environment
Material
Cover Plastic (PPS)
Solenoid Steel, nickel-plated
Housing material Die-cast aluminum
Weight
Net 0,3 kg
Ambient temperature -25 ... 50 °C
Degree of protection IP67
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Connection
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
Guard locking principle Open-circuit current principle
Locking force F
(Not monitored, in axial direction) at UCM?24V 650 N
Adhesive force
due to remanence 10 N -25% ... +25%
Electrical connection ratings
Operating voltage DC
UCM 24 V DC -15% ... 10%
Current consumption
UB 100 mA
Power consumption 2,5 W
Solenoid duty cycle 100 %
Work area
Center offset -2,5 ... +2,5 mm
''