Описание

Function Radio controlled safety module
Frequency band 433 / 434, 869 MHz
Safety inputs max. 3
Safety outputs 3 NO, 2 NO / 1 NC
Semiconductor inputs max. 8
Semiconductor outputs max. 8
Connection PS/PC/PT
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
SIL according to IEC/EN 61508 3
SIL according to IEC/EN 61511 3
Width 45 mm
Type UH 6900
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 Machine directive 2006/42/EG DIN EN 574: Safety of machinery - Two-hand control devices - DIN EN 300 220: Electromagnetic compatibility and Radio spectrum Matters(ERM) - Short Range Devices (SRD) - Radio equipment to be used inthe 25 MHz to 1000 MHz frequency range with power levels ranging upto 500 mW Depending on the operating mode, to connect:- E-stop push-button (2-channel), safety gate, LC (non-contact safetysystem, for example light curtain) of the type 4 in accordance withEN 61 496 or the two-hand type IIIA in accordance with DIN EN 574.- 1 start button- Changeover switch (2-channel) to indicate radio use in theSafety operation with optional radio control operating mode For two-way communication via radio:- Safety shut-down commands- Signals from 8 non-safety-relevant DC 24 V inputs at 8 non-safetyrelevantDC 24 V semiconductor outputs Broken wire and short circuit monitoring function with error indication Semiconductor output to indicate poor or no radio control 2 semiconductor outputs for status indication LEDs to indicate- status of module- status of all inputs and outputs- the radio transmission and its quality Width: 45 mm''